FS40 / FS40LF探頭根據(jù)DIN EN 2004-1和ASTM E 1004來(lái)測(cè)量非磁性金屬材料的電導(dǎo)率
市場(chǎng)價(jià):
優(yōu)惠價(jià):0.00
聯(lián)系人:朱盛
聯(lián)系電話:021-58951071
手機(jī)號(hào):15921165535
探頭根據(jù)DIN EN 2004-1和ASTM E 1004來(lái)測(cè)量非磁性金屬材料的電導(dǎo)率。由于集成了溫度傳感器,所有探頭都適合進(jìn)行溫度校正的測(cè)量,并自動(dòng)顯示標(biāo)準(zhǔn)化為20°的電導(dǎo)率值 C(68°F)。 所有探頭均以不同的頻率工作,因此能夠測(cè)量各種材料深度。 使用的測(cè)量方法可以進(jìn)行無(wú)接觸測(cè)量,也可以在非導(dǎo)電面漆(如漆面或塑料蓋)下進(jìn)行測(cè)量??捎糜冢?/span>
? 物料分類(lèi)
? 檢查熱損傷和材料疲勞
? 關(guān)于熱處理材料的硬度和強(qiáng)度的結(jié)論
? 金屬純度的測(cè)定
? 合金質(zhì)量標(biāo)準(zhǔn)
? 熱噴涂層評(píng)估
? FS40LF,用于測(cè)試硬幣合金和小貴金屬的真?zhèn)蔚母郊庸δ?/span>
Probe FS40 and FS40LF 技術(shù)參數(shù) | ||
FS40 | FS40LF | |
探頭設(shè)計(jì): | Axial single tip probes with spring-loaded measuring system | |
應(yīng)用: | Determination the electrical conductivity of non-ferrous metals (NF) | |
測(cè)量范圍: | 5... 108 %IACS | |
探頭頻率: | 60 kHz, 120 kHz, 240 kHz & 480 kHz | 15 kHz, 30 kHz, 60 kHz & 120 kHz |
誤差: | Trueness 1...100 %IACS: ≤ 2 % of nominal value | 1...100 %IACS: ≤ 1 % of nominal value |
Based on Fischer factory calibration standards with +20°C (+68°F) material temperature | ||
重復(fù)精度: |
Depending on probe frequency
60 kHz: ≤ 0.10 %IACS of reading
120 kHz: ≤ 0.15 %IACS of reading
240 kHz: ≤ 0.20 %IACS of reading
480 kHz: ≤ 0.35 %IACS of reading
|
Depending on probe frequency
15 kHz: ≤ 0.1 %IACS of reading
130 kHz: ≤ 0.1 %IACS of reading
160 kHz: ≤ 0.1 %IACS of reading
120 kHz: ≤ 0.15 %IACS of reading
|
Based on Fischer factory calibration standards, 5 single readings per standard, standard with +20°C material temperature | ||
Influences: | Depending on material and used probe frequency - The following values are valid for a sufficient material thickness which depends on the used probe frequency | |
Material Thickness Th:
![]() |
No measurement deviation within the trueness for Th ≥ Thmin Depending on the electrical conductivity of the material the minimal material thickness Thmin can be computed according to the following equation: | |
![]() |
f = Probe frequency in Hz
σ = Electrical conductivity of the material in %IACS
K ≈ 0.9, specific probe factor
|
|
Examples Depending on probe frequency
460 kHz: ≤ 0.10 %IACS of reading
120 kHz: ≤ 0.15 %IACS of reading
240 kHz: ≤ 0.20 %IACS of reading
480 kHz: ≤ 0.35 %IACS of reading
|
Examples Depending on probe frequency
15 kHz: ≤ 0.1 %IACS of reading
130 kHz: ≤ 0.1 %IACS of reading
160 kHz: ≤ 0.1 %IACS of reading
120 kHz: ≤ 0.15 %IACS of reading
|
|
Edge Distance (R), Specification From Probe Tip Centre: | For all probe frequencies- No measurement error within the trueness as of R ≥ 7 mm / 0.28" - Probe needs a minimum of R = 7 mm / 0.28" | |
![]() |
Measuring spot in the centre of the circular surface | |
Edge Distance (X), Specification From Probe Tip Centre: | For all probe frequencies - No measurement error within the trueness as of X ≥ 7 mm / 0.28" | |
Measuring spot |
![]() |
|
Curvature (R), measurement deviation from the nominal value with reference to master calibration on flat surface: |
For 60, 120, 240, 480 kHz
Compensation of curvature for R = 3...50 mm (0.12...1.97" ) by entering the diameter of curvature into the instrument No measurement error within the trueness as of R ≥ 50 mm / 1.97"
|
For 15 kHz
No measurement error within the trueness as of R ≥ 48 mm / 1.89" Error ≥ 10 % for R ≥ 10.3 mm / 0.41"
For 30 kHz
No measurement error within the trueness as of R ≥ 45 mm / 1.77" Error ≥ 10 % for R ≥ 9.5 mm / 0.37"
For 60 kHz and 120 kHz
Compensation of curvature for R = 3... 50 mm (0.12...1.97") by entering the diameter of curvature into the instrument No measurement error within the trueness as of R ≥ 50 mm / 1.97"
|
Measurement with measurement prism (grip ring 2) from the scope of supply. Probe needs a minimum of R = 1 mm / 0.04" |
![]() |
|
Distance Compensation (Measurement through a lacquer or plastic coating): |
Thickness of an air gab, plastic foil or lacquer coating. Distance compensated up to a thickness of 500 μm / 0.02" max. error: 1 % of reading |
|
Valid for measuring range - 0.5...108 %IACS | Valid for measuring range - 5... 100 %IACS | |
允許的工作環(huán)境溫度 | -10°C...+40°C / +14°F...+104°F | |
表面溫度 | max. +40≥C / +104°F | |
防潮 | No | |
針尖材料 | Plastic | |
針尖可更換: | No | |
測(cè)量方法: | 相敏渦流法 | |
標(biāo)配: | Probe, measurement prism (grip ring 2), Cu standard approx. 100 %IACS | |
尺寸: | Cable length: 1.5 m / 59.06", other cable lengths on request | |
![]() |